LED T10 RETROFIT: COMMERCIAL REPLACEMENT LED TUBE - GREEN CHOICE

Energy use is a leading cost for many organizations, with a direct impact on the environment and cost. Now there is an alternative to the cost, health and environment issues surrounding fluorescent lighting. The patented LED T10 replacment can trim 50-60% of lighting energy cost with a 50% reduction in carbon foot print.
BENEFITS
    • Patented thermal heat management. keeps lamps at cool
    • 50-60% Savings on Lighting Cost
    • Reduced Carbon
    • Pin for Pin Replacement on T12/T10 for Easy Retro-Fit
    • Totally Recyclable!
    • UL Approved US &
Canada
    • Instant-On, No Flicker
    • Low Heat Output – Saves on A/C Cost
    • Motion Sensor Capable
    • Shatter Proof Plastic & Anti-Glare Coating
    • >50,000 Hour Life = Less Maintenance
    • 2 Year Warranty
    • Operating Range from -13 F to 104 degrees F
    • Operating voltage: AC110-277V 50/60Hz
    • No driver required (built in).
    • No noise ballast

MODEL # DESCRIPTION WATTS SIZE KELVINS PRICE
LDW-TL30A012 LED LAMP 16 W  4 FT 4000-6000 $89.00 EA
LD-TL30A015 LED LAMP 20 W  4 FT 4000-6000 $99.00 EA

Light it Right is a commercial incentive program aimed at those of you with a business in one of five sectors to encourage you to get rid of your old wasteful and expensive lighting and replace it with a more efficient system – with the added benefit of seeing a rebate cheque at the end for your efforts.
SEE HERE FOR MOR INFORMATION: http://www.lightitright.ca/

 

 

Environmental & Social Responsibility
    • Go Green!
    • Less greenhouse gases
    • Recyclable
    • Reduced carbon footprint
Health & Safety
    • 100% Recyclable
    • No UV and Low RF
    • No Mercury & No Lead
    • Shatter proof
    • Anti-glare & Instant
Financial
    • Save 60-70% on lighting energy cost!
    • Low heat output = A/C savings
    • >50,000 hour life = Less maintenance
    • LEED* Points *LEED- Leadership In Energy & Environmental Design Green Rating System.

A=0.59M a=0.604M
B=0.89M b=0.91M
C=1.2M c=1.214M
D=1.5M d=1.514M


Emission Reductions:                                                                         
The below example shows the CO2 produced by 100 Lamps
(4200 hours = 14 hrs daily M-F & some Sat/Sun hrs for cleaning/OT)

Carbon Dioxide for 100 T12 40w Fluorescent
(40w x 4200 hrs x 100)/1000 x .0008=13.44 TONS/yr

For 100 T8 32w Fluorescent = 10.75 TONS/yr

For 100 T5 28w Fluorescent = 9.41 TONS/yr

For 100 15w LED = only 5.04 TONS/yr
 
      That's a 65% Carbon Footprint Reduction!

Easy for electricians to replace existing Fluorescent  T8 to LED T8. No driver or ballast required. Operating voltage: AC110-277V 50/60Hz.

Currently, the most efficacious white LEDs can perform similarly to fluorescent lamp. However, LED efficacy doesn’t tell the whole story. Good T8 LED replacement lamps shall combine high efficacy and brand LEDs, excellent thermal management, and sophisticated optical design. Conversely, poorly-designed T8 LED replacement lamps using even the best LEDs may be no more efficient or no longer life over existing T8 fluorescent lamps.

One of the most basic decision factors for T8 LED replacement lamp selection is longevity of the lamp. However, the lighting industry has very limited direct experience with long-term performance and reliability of T8 LED replacement lamps.

In summary, T8 LED replacement lamp life is not identical to estimated LED life. T8 LED replacement lamp life is also a function of the power supply, operating temperatures, thermal management, materials and electrical and material interfaces. How can T8 LED replacement lamp reliability be assessed? Some things to look for:

- Use of high quality LEDs from brand suppliers who publish reliability data.

- Superior heat sink design to dissipate heat, minimizing T8 LED replacement lamp temperature (for example, board, case, or solder joint temperature) as low as possible.

- Optical specification from independent testing laboratory or manufacturer in-house testing.

- Warranty offered by the manufacturer should be at least comparable to traditional fluorescent lamp for the application under consideration.

- Any test data available about longer term performance of T8 LED replacement lamp.

Common T8 LED replacement lamp

Common T8 LED replacement lamp features a linear array of 5mm DIP LEDs (suitable for indication applications, ranging from 60 to 400 LEDs per lamp), with airtight clear tubular plastic or glass covers as heat sink and diffuser, and integrated driver (non-isolated constant voltage type). As plastic and glass are not good heat conduction materials, this kind of design will cause heat buildup inside the tube, depreciate lumen quickly and shorten useful life of T8 LED replacement lamp.

In contrast, DURA-BRIGHT™ T8 LED replacement lamp features a linear array of imported high quality SMD LEDs (ranging from 30 to 88 LEDs per lamp), with patented design of aluminum housing as heat sink, stripped PC cover as diffuser and UL listed integrated driver (isolated constant current type).


 

Copyright © All Rights Reserved. Reproduction in whole or in part in any form or medium without expressed  written permission of LED WORLD INC. is prohibited. Prices in USD. We are not responsible for errors or omissions regarding products on this site. Specifications and prices are subject to change without notice. *Noted trade marks are owned by there registered company. Updated Thursday August 19, 2010